• TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
  • TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
  • TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
  • TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
  • TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
  • TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

After-sales Service: Life Time
Warranty: 12 Months Excellent for Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus pictures & photos
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
US $96,000-162,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3760
Voltage Output
NONE
Current Output
20mA~120A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05
Test Positions
12(Max)
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
100.00cm * 80.00cm * 80.00cm
Package Gross Weight
50.000kg

Product Description

TD3760 Complex Waveform Testing Apparatus
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

1. Summary

TD3760 is an AC power device specially designed for complex waveform current influence test of new AC energy meters. It meets the test requirements of relevant current influence in OIML R46. The device directly outputs complex current waveforms with high stability and accuracy through the three phase precision standard power source, which can complete the following test items.
(1)Impact Test of DC and Even Harmonics (The device can directly output half-wave current, no longer use the traditional scheme (rectifier diode) )
(2)Impact Test of Harmonic in Voltage-current Circuits,
(3)Impact Test of Inter-harmonic in the Current Circuits
(4)Impact Test of Odd Harmonic in Current Circuits
(5)High-order harmonic test
(6)Burden current fast change test
Up to 12 test positions. Accuracy Class 0.05.

 

2. Features

  1. Impact Test of Harmonic in Voltage-current Circuits: Built in square-wave, peaked wave, inter-harmonic and other schemes.
  2. Impact Test of Inter-harmonic in the Current Circuits: The device can directly output the inter-harmonic.
  3. Impact Test of Odd Harmonic in Current Circuits: The device can directly output the odd harmonic.
  4. High-order harmonic test: Built in high-order harmonic test schemes. So it automatically superposes the 15fnom to 40fnom sweep signals to the voltage and current loops and reads the data of each harmonic to measure the error offset caused by the high-order harmonic.
  5. Burden current fast change test: The user can set the duration of ton and toff, as well as the total time for a single test. The current switches at zero crossing and switches off and on within one nominal frequency period. The repetition time of single test was more than 4 hours.
  6. Communication: Communicate with DUT through RS-485 communication port.
  7. Multi-position verification platform: Optional 3,6,12,16 positions.
 

3. Typical output waveform

3.1 Half-wave rectification waveform (DC and Even Harmonics)

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
 

3.2 Waveform of the Impact Test of Harmonic

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
                                                       
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
                                                          

3.3 Inter-harmonic

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
 

3.4 Odd Harmonic

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
 

4. Specifications

4.1 AC Voltage Output

Range Resolution Short-term Stability ( % / min ) Accuracy
±(ppm of reading + ppm of range) [1]
Distortion Factor ( % )
60 V 0.1 mV 0.01 120 + 80 < 0.3
120 V 1 mV 0.01 120 + 80 < 0.3
240 V 1 mV 0.01 120 + 80 < 0.3
480 V 1 mV 0.01 120 + 80 < 0.3
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 0 V~264 V, 6-digits display, load capacity: 15VA/ (phase · position)
  2. Symmetry: Voltage ≤ 0.2%, Phase ≤ 0.5°
  3. Protective function: Short-circuit protection, Overload protection
 

4.2 AC Current Output

Range Resolution Short-term Stability ( % / min ) Accuracy
±(ppm of reading + ppm of range)
Distortion Factor ( % )
100 mA 1 μA 0.01 200 + 100 < 0.2
200 mA 1 μA 0.01 200 + 100 < 0.2
500 mA 1 μA 0.01 200 + 100 < 0.2
1 A 10 μA 0.01 200 + 100 < 0.2
2 A 10 μA 0.01 200 + 100 < 0.2
5 A 10 μA 0.01 200 + 100 < 0.2
10 A 100 μA 0.01 200 + 100 < 0.2
20 A 100 μA 0.01 200 + 100 < 0.2
50 A 100 μA 0.01 200 + 100 < 0.2
100 A 1 mA 0.01 200 + 100 < 0.2
  1. Output range: 20mA~120 A@ full wave, 6-digits display
  2. Symmetry: Current ≤ 0.5%, Phase ≤ 0.5°
  3. Protective function: Open-circuit protection, Overload protection, Overheating protection

4.3 Frequency / Phase / Harmonic

Type Range of Regulation Accuracy
Frequency 45.000 0Hz~100.000 Hz 50 ppm*RD
Phase 0.000°~359.999° 0.012°
Harmonic Output the 2nd ~ 63st @ 50 Hz / 60 Hz (support single or multiple simultaneous stacking), harmonic content and phase are programmable (Amplitude: 0~40% , Phase: 0.0°~359.9°).
 

4.4 Power / Electrical Energy

  1. Uncertainty of Measurement (k=2): 0.05%*RD
  2. Output Power Stability: 0.02% / 2min
  3. Power/Electric Energy Measuring Range: The combination of AC voltage and current range
  4. Power Factor Measuring Range: -1.000 00…0.000 00…1.000 00
  5. Standard Electric Energy Pulse output: High frequency pulse output port outputs 60KHz at full range, low frequency pulse output port outputs 6Hz at full range;
  6. Standard Energy Pulse Input: Frequency ≤ 200 kHz, Voltage: 0...3.3 V...24 V
  7. Electric Energy Error Display: Auto, resolution is 0.0001%.

5. General Specifications

Power Supply AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
Warm Up Time 30 min
Temperature Operating Temperature: 18°c~28°c;
Storage Temperature: -10°c~55°c
Humidity Performance Operating Humidity: < 80% @ 30°c, < 70% @ 40°c, < 40% @ 50°c
Storage Humidity: (20%~80%) R·H, Non-Condensing
Communication Interface RS232, RS485, LAN

6. Ordering Information

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

 
Company Profile
 

TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

TD3760 Complex Waveform Current Influence of Energy Meter Testing ApparatusTD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus pictures & photos
TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus
US $96,000-162,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013