Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 months Excellent After-sales Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
☆ Verification DC Energy Meter |
|
☆ Wide Range DC Power Output |
|
☆ DC+AC(DC ripple)Output |
|
☆ Clock Check Function |
|
☆ Auxiliary Power Supply(Power Consumption Test) |
|
☆ Adjustable Power Supply Voltage(Voltage Dip and Short Interruption test) |
|
☆ Voltage Reverse Polarity Output |
|
☆ Professional Test Software |
|
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) [1] |
Maximum Burden Current (mA) | Ripple ( % ) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||||
100 mV | 0.1 μV | 0.01 | 0.005 | 120 + 80 | 80 + 60 | 100 | < 0.2 |
300 mV | 0.1 μV | 0.008 | 0.004 | 120 + 80 | 80 + 60 | 100 | < 0.2 |
1 V | 1 μV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 100 | < 0.2 |
3 V | 1 μV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 100 | < 0.2 |
10 V | 10 μV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 100 | < 0.2 |
30 V | 10 μV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 50 | < 0.2 |
100 V | 0.1mV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 50 | < 0.2 |
300 V | 0.1mV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 50 | < 0.2 |
1000 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 15 | < 0.2 |
1500 V [2] | 1 mV | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 10 | < 0.2 |
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). [2]:1500V range is an option. |
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) |
Maximum Burden Voltage (V) | Ripple ( % ) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||||
250 μA | 0.1 nA | 0.010 | 0.005 | 120 + 80 | 80 + 60 | 12 | < 0.5 |
500 μA | 0.1 nA | 0.010 | 0.005 | 120 + 80 | 80 + 60 | 12 | < 0.5 |
1 mA | 1 nA | 0.005 | 0.003 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
2 mA | 1 nA | 0.005 | 0.003 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
5 mA | 1 nA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
10 mA | 10 nA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
25 mA | 10 nA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
50 mA | 10 nA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 12 | < 0.5 |
100 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
200 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
500 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
1 A | 1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
2.5 A | 1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
5 A | 1 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
10 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
20 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
50 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
100 A | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
250 A[3] | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
500 A[3] | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 50 + 40 | 3 | < 0.5 |
NOTES: [3] 250 A,500 A current range is optional Accessories. |
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) |
Maximum Burden Current (mA) | Ripple ( % ) |
1 mV | 10 nV | 0.1 μVrms | 120 + 0.3 μV | - | < 0.2 |
3 mV | 10 nV | 0.3 μVrms | 120 + 1 μV | - | < 0.2 |
10 mV | 0.1 μV | 1 μVrms | 120 + 3 μV | - | < 0.2 |
30 mV | 0.1 μV | 0.002 | 120 + 80 | - | < 0.2 |
100 mV | 1 μV | 0.002 | 120 + 80 | - | < 0.2 |
300 mV | 1 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
1 V | 10 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
4 V | 10 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
NOTES: [4]When independently calibrating the indirect connected DC energy meter , it can be used as its current input (corresponding shunt voltage). |
DC Power/Electric Energy | Range | Combination of DC voltage and DC current(or DC small-signal) |
Accuracy | Voltage uncertainty of measurement+ current uncertainty of measurement (or DC small-signal voltage uncertainty of measurement) | |
Electric Energy Pulse | Standard Electric Energy Pulse Output | High frequency full range value corresponds to 60 kHz; Low frequency full range value corresponds to 6 Hz; |
Pulse Output Frequency | Output frequency jitter time<10 μs | |
Standard Electric Energy Pulse Input | 2×10-7 | |
Electric Energy Error Display | Signal amplitude is 5 V,TTL level; Can accept ≤200 kHz high-frequency pulse; FH=60 kHz × power value÷ voltage range value ÷ current range value FL=60 kHz × power value÷ voltage range value ÷ current range value |
|
Electric Energy Error Display | Auto display,resolution is 0.0001% | |
Difference At Different Epitope | Position difference at different positions< ± 0.025% |
Voltage Range | Ripple Adjustable Range (Effective Value) |
Accuracy(k = 2) (%*RG) |
Uncertainty Limit of Electric Energy Change Caused by Ripple(%*RD) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||
3 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
10 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
30 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
100 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
300 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
1000 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
1500 V | 0%~20.00% | 0.05 | 0.02 | 0.05 | 0.02 |
Small-Signal Voltage Range | Ripple Adjustable Range (Effective Value) |
Accuracy(k = 2) (%*RG) |
Uncertainty Limit of Electric Energy Change Caused by Ripple (%*RD) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||
30 mV | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
100 mV | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
300 mV | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
1 V | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
4V | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
Current Range | Ripple Adjustable Range (Effective Value) |
Accuracy(k = 2) (%*RG) |
Uncertainty Limit of Electric Energy Change Caused by Ripple (%*RD) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||
10 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
20 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
50 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
100 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
200 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
500 mA | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
1 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
2 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
5 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
10 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
20 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
50 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
100 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
200 A | 0%~40.00% | 0.05 | 0.02 | 0.05 | 0.02 |
500 A | 0%~20.00% [5] | 0.05 | 0.02 | 0.05 | 0.02 |
NOTES[5]:When the maximum current is 100A, the ripple under 100A range is 0%~20.00%. |
DC Power Output | Output Voltage | 24 V / 48 V |
Output Range | 6 V~62.4V | |
Maximum Burden Current | 300 mA per position | |
Uncertainty of Power Consumption Measurement | Better than 0.1 VA | |
AC Power Output | Output Voltage | 220 V |
Output Range | 110 V~286 V | |
Maximum Burden Current | 30 mA per position | |
Uncertainty of Apparent Power Consumption Measurement | Better than 0.2 VA | |
Uncertainty of active power Consumption measurement | Better than 0.2 W |
Power Supply | AC (220±22) V,(50±2) Hz |
Temperature Performance | Working temperature:15°C~30°C; Calibration temperature:18°C~28°C; Storing temperature:-20°C~70°C |
Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storing humidity:(20%~80%) R·H,no dewing |
Interface | RS232,RS485,RJ45,USB |