Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 months Excellent After-sales Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
☆ Verification of DC Energy Meter |
|
☆DC Energy Meter Frame |
|
☆ Clock check function | ||
|
||
☆ Auxiliary power supply | ||
|
☆Four wire small signal voltage source |
|
☆ Professional test software |
|
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) [1] |
Maximum Burden Current (mA) | Ripple ( % ) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||||
100 mV | 1 μV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
300 mV | 1 μV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
1 V | 10 μV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
3 V | 10 μV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
10 V | 0.1 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
30 V | 0.1 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
100 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 50 | < 0.2 |
300 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 30 | < 0.2 |
600 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 10 | < 0.2 |
1000 V | 10 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 10 | < 0.2 |
1500 V [2] | 10 mV | 0.005 | 0.002 | 120 + 80 | 80 + 20 | 10 | < 0.2 |
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). [2]:1500V range is an option. |
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) |
Maximum Burden Voltage (V) | Ripple ( % ) | ||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||||
200 μA | 1 nA | 0.03 μA | 0.02 μA | 120+0.06 μA | 60+0.04 μA | 12 | < 0.5 |
500 μA | 1 nA | 0.05 μA | 0.03 μA | 120+0.10 μA | 60+0.06 μA | 12 | < 0.5 |
1 mA | 10 nA | 0.08 μA | 0.04 μA | 120+0.15 μA | 60+0.08 μA | 12 | < 0.5 |
2 mA | 10 nA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
5 mA | 10 nA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
10 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
20 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
50 mA | 0.1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
100 mA | 1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
200 mA | 1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 12 | < 0.5 |
500 mA | 1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3.5 | < 0.5 |
1 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 0.5 |
2 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 0.5 |
5 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 0.5 |
10 A | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 0.5 |
20 A | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 0.5 |
50 A | 0.1 mA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 1.0 |
100 A | 1 mA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 | < 1.0 |
Note: [3] As the current input of the direct connected DC energy meters |
Range | Resolution | Short Term Stability (% / min) |
Accuracy (k=2) (ppm of reading + ppm of range) |
Maximum Burden Current (mA) | Ripple ( % ) |
1 mV | 10 nV | 0.1 μVrms | 120 + 0.3 μV | - | < 0.2 |
3 mV | 10 nV | 0.3 μVrms | 120 + 1 μV | - | < 0.2 |
10 mV | 0.1 μV | 1 μVrms | 120 + 3 μV | - | < 0.2 |
30 mV | 0.1 μV | 0.002 | 120 + 80 | - | < 0.2 |
100 mV | 1 μV | 0.002 | 120 + 80 | - | < 0.2 |
300 mV | 1 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
1 V | 10 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
4 V | 10 μV | 0.002 | 120 + 80 | ≤ 10 | < 0.2 |
Note: [4] When the indirect connected DC energy meters is verified separately, it can be used as its current input (corresponding to the shunt voltage) |
DC Power/Electric Energy | Range | Combination of DC voltage and DC current (or DC small signal voltage) |
Accuracy | Uncertainty of voltage measurement+uncertainty of current measurement (or uncertainty of DC small signal voltage measurement) | |
Electric Energy Pulse | Standard Electric Energy Pulse Output | High frequency full range value corresponds to 60 kHz; Low frequency full range value corresponds to 6 Hz; |
Pulse Output Frequency | Output frequency jitter time<10 μ s | |
Standard Electric Energy Pulse Input | Signal amplitude is 5V, TTL level; Able to receive high-frequency pulses ≤ 150 kHz; FH=60 kHz × Power value ÷ voltage range value ÷ current range value FL=60 kHz × Power value ÷ voltage range value ÷ current range value ÷ 10000 |
|
Electric Energy Error Display | Automatic display, resolution 0.0001% | |
Difference At Different Epitope | < ± 0.025% |
DC Power Output | OutputVoltage | 24 V / 48 V |
Maximum Burden Current | 120 mA / Epitope | |
Protection Function | Replaceable fuse protection | |
AC Power Output | Output Voltage | 220( Visolated) |
Maximum Burden Current | 20 mA / Epitope | |
Protection Function | Replaceable fuse protection |
Power Supply | AC (220±22) V,(50±2) Hz |
Temperature Performance | Working temperature:0°C~45°C; Calibration temperature:18°C~28°C; Storage temperature:-20°C~70°C |
Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storage humidity:(20%~80%) R·H,No condensation |
Interface | RS232 |