• TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  • TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  • TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  • TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  • TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  • TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator

TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator

After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator pictures & photos
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
US $3,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TI1000
Customized
Non-Customized
ACV/DCV output
10 mV ~ 1020V
Interface
RS232; LAN; USB
TI1000-B
Frequency: DC, AC 45 Hz ~ 2 kHz; Optimum accuracy:
TI1000-C
Frequency: DC, AC 10 Hz ~ 20 kHz; Optimum accuracy
Transport Package
Package for Exporting
Specification
5kg; 215 mm (W) x 252 mm (D) x 88 mm(H),
Trademark
TUNKIA
Origin
China

Packaging & Delivery

Package Size
40.00cm * 50.00cm * 15.00cm
Package Gross Weight
10.000kg

Product Description

TI1000 Precision AC/DC Voltage Calibrator 
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator

1. Summary

TI1000 is an AC\DC voltage source with high stability and precision. it is applied for calibrating digital voltmeters\multimeters on-site, e.g, industrial production lines, etc.
 

2. Features

  1. ACV\DCV output: 10 mV ~ 1020 V
  2. Standard version(TI1000-B) and advanced version(TI1000-C) are available
  3. Typical specifications of the standard version(TI1000-B):
          Frequency: DC, AC 45 Hz ~ 2 kHz.
          Optimum accuracy: DC 100 ppm, AC 200 ppm.
      4.Typical specifications of the advanced version(TI1000-C):
          Frequency: DC, AC 10 Hz ~ 20 kHz
         Optimum accuracy: DC 35ppm, AC 100ppm.
     5. The maximum output power of AC and DC voltage is up to 10 VA
     6. Shortcut output keys
     7.Programmable calibration schemes
     8.RS232,LAN and USB communication interfaces
 

3. Application


Calibrate voltage measuring instruments
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  1. Suitable for calibrating AC/DC voltmeters or voltage measurement of multimeter.
 

Convenient Operation
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  1. The front panel has 10 shortcut keys that can output the corresponding value on the screen with one key.
 
Calibration Scheme Setting
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
  1. Multiple calibration schemes can be edited and stored for the calibration of multimeter with different specifications.

4. Specifications(TI1000-B)

4.1 DC Voltage

Range Voltage Output Resolution Short-term Stability (%/min) Accuracy
±(%*RD+mV) [1]
Maximum load [source internal resistance]
300 mV ±(10.0000 mV ~ 330.0000 mV) 100 nV 0.005 0.008 + 0.006 [60 Ω]
3 V ±(0.300000 V ~ 3.300000 V) 1 μV 0.005 0.008 + 0.06 20 mA
30 V ±(3.00000 V ~ 33.00000 V) 10 μV 0.005 0.008 + 0.6 15 mA
300 V ±(30.0000 V ~ 330.0000 V) 100 μV 0.005 0.008 + 6 10 mA
1000 V ±(300.000 V ~ 1020.000 V) 1 mV 0.005 0.008 + 20 10 mA
Note[1]: RD is the reading value, same below.
  1. Output range: ± (10 mV ~ 1020 V)
  2. 7 digits display
  3. Adjustment fineness: 0.002%*RG
  4. Ripple factor: < 0.1%
  5. Protection function: short-circuit protection, overload protection and over-heat protection

4.2 AC Voltage

Range Voltage Output Frequency Resolution Accuracy
±(%*RD+mV) [1]
Maximum load [source internal resistance]
300 mV 10.0000 mV ~ 330.0000 mV 45 Hz ~ 400 Hz 100 nV 0.02 + 0.01 [60 Ω]
400 Hz ~ 2 kHz 0.03 + 0.01
3 V 0.300000 V ~ 3.300000 V 45 Hz ~ 400 Hz 1 μV 0.02 + 0.1 20 mA
400 Hz ~ 2 kHz 0.03 + 0.1
30 V 3.00000 V ~ 33.00000 V 45 Hz ~ 400 Hz 10 μV 0.02 + 1 15 mA
400 Hz ~ 2 kHz 0.03 + 1
300 V 30.0000 V ~ 330.0000 V 45 Hz ~ 400 Hz 100 μV 0.02 + 10 10 mA
400 Hz ~ 2 kHz 0.03 + 10
1000 V 300.000 V ~ 1020.000 V 45 Hz ~ 400 Hz 1 mV 0.02 + 30 10 mA
400 Hz ~ 1 kHz 0.03 + 30
  1. Output range: 10 mV ~ 1020 V
  2. 7 digits display
  3. Adjustment fieness: 0.002%*RG
  4. Distortion: < 0.3%
  5. Protection function: short-circuit protection, overload protection and over-heat protection

4.3 Sinusoidal Wave Frequency

Range Resolution Accuracy ±(%*RD)
45.00000 Hz ≤ F ≤ 99.99999 Hz 10 μHz 0.01
100.0000 Hz ≤ F ≤ 999.9999 Hz 100 μHz 0.01
1.000000 kHz ≤ F ≤ 2.000000 kHz 1 mHz 0.01
 

5. Specifications(TI1000-C)

5.1 DC Voltage

Range Voltage Output Resolution 24 hour Stability (Tcal±1°C) Accuracy
1 year (Tcal±5°C)
Maximum load [source internal resistance]
±(ppm*RD+mV)
100 mV ±(10.0000 mV ~ 110.0000 mV) 100 nV 13 + 0.003 25 + 0.004 [60 Ω]
1 V ±(0.100000 V ~ 1.100000 V) 1 μV 13 + 0.005 25 + 0.01 20 mA
10 V ±(1.00000 V ~ 11.00000 V) 10 μV 13 + 0.05 25 + 0.1 15 mA
100 V (10.0000 V ~ 110.0000 V) 100 μV 13 + 0.5 25 + 1 10 mA
1000 V (100.000 V ~ 1020.000 V) 1 mV 13 + 6 25 + 10 10 mA
  1. Output range: ± (10 mV ~ 11 V),11 V ~ 1020 V
  2. 7 digits display
  3. Adjustment fineness: 0.002%*RG
  4. Ripple factor: < 0.1%
  5. Protection function: short-circuit protection, overload protection and over-heat protection

5.2 AC Voltage

Range Voltage Output Frequency Resolution Accuracy
1 year (Tcal±5°C)
±(ppm*RD+mV)
Maximum load [source internal resistance]
100 mV 10.0000 mV ~ 110.0000 mV 10 Hz ~ 45 Hz 100 nV 100 + 0.02 [60 Ω]
45 Hz ~ 2 kHz 60 + 0.02
2 kHz ~ 20 kHz 80 + 0.02
1 V 0.100000 V ~ 1.100000 V 10 Hz ~ 45 Hz 1μV 100 + 0.04 20 mA
45 Hz ~ 2 kHz 60 + 0.04
2 kHz ~ 20 kHz 80 + 0.04
10 V 1.00000 V ~ 11.00000 V 10 Hz ~ 45 Hz 10 μV 100 + 0.4 15 mA
45 Hz ~ 2 kHz 60 + 0.4
2 kHz ~ 20 kHz 80 + 0.4
100 V 10.0000 V ~ 110.0000 V 45 Hz ~ 2 kHz 100 μV 60 + 4 10 mA
1000 V 100.000 V ~ 1020.000 V 45 Hz ~ 2 kHz 1 mV 60 + 40 10 mA
  1. Output range: 10 mV ~ 1020 V
  2. 7 digits display
  3. Adjustment fineness: 0.002%*RG
  4. Distortion: < 0.3%
  5. Protection function: short-circuit protection, overload protection and over-heat protection
 

5.3 Sinusoidal Wave Frequency

Range [1] Resolution Accuracy
1 year (Tcal±5°C) (%*RD)
10.00000 Hz ≤ F ≤ 99.99999 Hz 10 μHz 0.01
100.0000 Hz ≤ F ≤ 999.9999 Hz 100 μHz 0.01
1.000000 kHz ≤ F ≤ 9.999999 kHz 1 mHz 0.01
10.00000 kHz ≤ F ≤ 20.00000 kHz 10 mHz 0.01
 

6. General Specifications

Power supply AC (220±22) V, (50±2) Hz
Maximum power consumption 100 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Operating environment 0°C ~ 55°C, 30%R·H ~ 80%R·H, non-condensing
Storage environment -30°C ~ 70°C, 10%R·H ~ 90%R·H, non-condensing
Communication interface USB×1,LAN×1,RS232×1
Dimensions 215 mm (W) × 252 mm (D) ×88 mm(H), feets excluded.
Display 3.5-inch color LCD
Weight About 5 kg
 
Company Profile
 

TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator

TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction CalibratorTUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator pictures & photos
TUNKIA High Precision Voltmeter Calibration Onsite voltage standard source Class 0.01 1020 V 2 kHz DC AC voltage multifunction Calibrator
US $3,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013