• TD3500  Single-Phase Energy Meters Test Bench
  • TD3500  Single-Phase Energy Meters Test Bench
  • TD3500  Single-Phase Energy Meters Test Bench
  • TD3500  Single-Phase Energy Meters Test Bench
  • TD3500  Single-Phase Energy Meters Test Bench
  • TD3500  Single-Phase Energy Meters Test Bench

TD3500  Single-Phase Energy Meters Test Bench

After-sales Service: Life Time
Warranty: 12 Months Excellent for Service
Application: Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD3500  Single-Phase Energy Meters Test Bench pictures & photos
TD3500  Single-Phase Energy Meters Test Bench
US $22,000-46,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3500
Power
Electricity
Voltage Output
264V
Current Output
120A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05 or 0.1
Frequency
45 Hz ~ 100 Hz
Minimum Current Output
1 mA
Multiple-position Test
6/12/16/24
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
120.00cm * 100.00cm * 90.00cm
Package Gross Weight
60.000kg

Product Description

TD3500 Verification Apparatus for Single-Phase Energy Meters 
TD3500 Single-Phase Energy Meters Test Bench

1. Summary

TD3500 is applied for verification of single-phase energy meters. It mainly consists of single-phase precision standard power source, verification platform, measurement and control platform, PC(optional) and verification software. TD3500 supports simultaneous verification of 6 ~ 24 single-phase electricity/mechanical energy meters with the same voltage/current range, different meter constant.
 

2. Verification Items

  1. Test of no-load
  2. Starting current test
  3. Intrinsic error
  4. Meter constant
  5. Daily reckoning error
 

3. Features

3.1 Basic Features

  1. Maximum output capacity: 264 V / 120 A.
  2. Fundamental frequency: 45 Hz ~ 100 Hz.
  3. Accuracy: class 0.05 or 0.1.
  4. Minimum current output: As low as 1 mA.
  5. Auto range: Automatic range switching and load matching.
  6. Energy measurement: Positive / negative active and reactive energy. 
  7. Daily reckoning error test: Built in standard clock tester.
  8. Automatic patrol inspection: Support automatic patrol inspection.
  9. Connection: Equipped with special pressure gauge holder.
  10. Communication: DUT through RS-485 port.
  11. Energy pulse: Electric and optical pulse sampling ports.
  12. Multiple-position test: Optional 6,12,16,24 positions.
  13. Mobile control unit: LCD touch screen for value output.
  14. Professional verification software: Support semi-automatic or fully automatic verification of the DUT, data management and certificate export. The software has the function of single point multiple tests, the test interval can be set, and the error curve can be drawn automatically.
 

3.2 Optional Features

  1. Harmonic output: Loadable 2nd ~21st harmonic @50 Hz / 60 Hz, harmonic content and phase are adjustable.
  2. Standard meter: Optional standard meter with Accuracy class 0.05 / 0.02.
 

4. Specifications

4.1 Three Phase Voltage Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) [1]
Distortion Factor
( % )
Class 0.05 Class 0.1 Class 0.05 Class 0.1
220 V 1 mV 0.01 0.02 200 + 50 300 + 200 < 0.3
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 0 V~264 V, 6-digits display, Load capacity: 15VA/ (phase · position)
  2. Protective function: Short-circuit protection, Overload protection
 

4.2 Three Phase Current Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) 
Distortion Factor
( % )
Class 0.05 Class 0.1 Class 0.05 Class 0.1
10 mA 0.1 μA 0.02 0.04 300 + 200 500 + 300 < 0.5
20 mA 0.1 μA 0.02 0.04 300 + 200 500 + 300 < 0.5
50 mA 0.1 μA 0.02 0.04 200 + 50 300 + 200 < 0.5
100 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
200 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
500 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
1 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
2 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
5 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
10 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
20 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
50 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
100 A 1 mA 0.01 0.02 200 + 50 300 + 200 < 0.5
  1. Output range: 1 mA~120 A, 6-digits display, load capacity: 30VA/ (phase · position)
  2. Protective function: Open-circuit protection, Overload protection

4.3 Frequency / Phase

Accuracy Class 0.05 Class 0.1
Frequency Measuring Range 45 Hz~100 Hz 45 Hz~100 Hz
Minimum Resolution 0.000 01 Hz 0.000 01 Hz
Accuracy ±0.005%*RD ±0.005%*RD
Phase
(I ≥ 50mA)
Measuring Range 0~360° 0~360°
Minimum Resolution 0.000 1° 0.000 1°
Accuracy ±0.012° ±0.024°
 

4.4 Power/ Energy

Current Range Power Factor Accuracy ±(% of reading) 
Class 0.05 Class 0.1
50 mA ≤ I ≤ 120 A 0.5L~1~0.5C 0.05%*RD 0.1%*RD
10 mA ≤ I < 50 mA 1 0.05%*RD 0.1%*RD
0.5L~1~0.5C 0.08%*RD 0.15%*RD
1 mA ≤ I < 10 mA 1 0.08%*RD 0.15%*RD
0.5L~1~0.5C 0.15%*RD 0.3%*RD
  1. Stability of output power: 0.02% / 2min (Class 0.05),0.05% / 2min (Class 0.1);
  2. Measuring range of P/E: Combination of AC voltage and AC current range;
  3. Measuring range of power factor: -1.000 00…0.000 00…1.000 00;
  4. Standard electric energy pulse output: High frequency pulse output port outputs 60KHz at full range, low frequency pulse output port outputs 6Hz at full range;
  5. Standard electric energy pulse input: Frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V;
  6. Electric energy error display: Auto, resolution is 0.0001%.
 

4.5 Clock

  1. Daily reckoning error limit: ±0.05 s/d
 

5. General Specifications

Power supply Single phase AC(220±22)V, (50±2)Hz
Warm up time 30min
Temperature performance Operating temperature: 5°C~45°C;
Storage temperature: -10°C~55°C.
Humidity performance Operating humidity: < 80% @ 30°C,< 70% @ 40°C, < 40% @ 50°C;
Storage humidity: (20%~80%) R·H, no condensation.
Communication interface RS232, RS485, LAN
Dimensions of test bench
(L*W *table H / total H, mm)
Position number 6 positions 12 positions 16 positions 24 positions
Manual wiring 1350*750*750/1415 -- -- --
Crimp wiring 1350*750*750/1415 1240*750*600/1782 1590*750*600/1782 2290*750*600/1782
Dimensions of computer desk
(L*W*H, mm)
No standard meter 1000*800*750
Standard meter 1500*800*750
 

6. Ordering Information

TD3500 Single-Phase Energy Meters Test Bench
Special Customized Function Selection Table
Tick Option function Description
  Harmonic output 2nd~21th
  Standard meter Class 0.05
  Other requirements  
 
Company Profile
 

TD3500 Single-Phase Energy Meters Test Bench

TD3500 Single-Phase Energy Meters Test BenchTD3500 Single-Phase Energy Meters Test Bench

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD3500  Single-Phase Energy Meters Test Bench pictures & photos
TD3500  Single-Phase Energy Meters Test Bench
US $22,000-46,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013