TH0500 Current Conversion Standard and Precision Current Transformers

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TH0500 Current Conversion Standard and Precision Current Transformers
  • TH0500 Current Conversion Standard and Precision Current Transformers
  • TH0500 Current Conversion Standard and Precision Current Transformers
  • TH0500 Current Conversion Standard and Precision Current Transformers
  • TH0500 Current Conversion Standard and Precision Current Transformers
  • TH0500 Current Conversion Standard and Precision Current Transformers
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TH0500
Application
Electromagnetic Instrument, Electrical Calibration
Power
Electricity
Customized
Non-Customized
Direct Type Nominal Input Current
0.1 A...200 A
Through-Core Type Input Current
500 A... 20 kA
Secondary Output Signal
Voltage Type (I/V) or Current Type (I/I)
Type I/I
Optimal Proportional Uncertainty up to 0.2ppm
Type I/V
Optimal Proportional Uncertainty up to 10ppm
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

 
TH0500 Current Conversion Standard and Precision Current Transformers

1. Summary

The TH0500 Precision Current Transformers based on the principle of the current comparator, it can produce an output current or voltage that varies directly with the input current from 0.1A to 20 kA. By the connection of a reference shunt burden on the output terminal when outputting an current or directly measuring the voltage when outputting an voltage the primary current can be deduced from the measured voltage . 

2. Features
(1)Supports two current access modes, through core and direct connected type respectively.
Direct connected type with the input current of 0.1 A…200 A
Through core type with the input current of 500 A…20 kA
 
(2)Secondary output signal is optional for current (I / I) or voltage (I/ V)
I/I:Optimum uncertainty of 0.2ppm
I/V:Optimum uncertainty of 10 ppm

(3)
Optional digital display function, support for digital signal output
 

3. Applications

(1)Establish DC / AC current precision measurement system
(2)Calibrate the DC / AC current source or ammeter
(3)Calibrate the DC current ratio standard (current comparator)
(4)Calibrate the DC current transformer / sensor
(5)Calibrate the DC current I/V transformers 
 
 Flexible current access and signal output mode
TH0500 Current Conversion Standard and Precision Current Transformers
  1. Current input is optional! direct connected type with the input current of 0.1 A... 200 A.
  2. through core type with the input current of 500 A... 20 kA.
The secondary output can be selected as a voltage type or a current type:
  1. Voltage output ( I/V ):nominal output 10 V.
  2. Current output ( I/I ):nominal output 0.1 A ... 5 A selected .
 

3.1 Application of type I/V TH0500

Establish current precision measurement system
TH0500 Current Conversion Standard and Precision Current Transformers
  1. Form a current measurement system withTH0500, precision voltmeter and high stability current source.
  2. Implement the measurement of a large current, or provide a DC / AC current signal
 
Calibrate High Current Source / meter
TH0500 Current Conversion Standard and Precision Current Transformers
  1. Another typical application of the type I / V transform is paired with a precision voltmeter to calibrate the AC high current standard source / meter.TH0500 Current Conversion Standard and Precision Current Transformers
Calibrate I/V conversion standards
 
  1. Using the I/V type TH0500, you can calibrate the DC shunt, current transducer and other I/ V transform devices in the following two methods.
  2. Calibration by difference method:The selected TH0500 is in the same proportion as the tested I/V, and a micro voltmeter such as a nanovoltmeter is used for calibration
  3. Calibration by voltage ratio method:The selected TH0500 is not proportional to the tested I / V and is calibrated using a voltage ratio measurement device.(Note: For the calibration of type I /I conversion standard such as current comparator and DC current transformer, type I/ I TH0500 is recommended as the standard; the secondary series standard resistance being tested I / I is also used as described in the method above figure.)

3.2 Application of Type I/I TH0500

Calibrate I/I conversion standards
TH0500 Current Conversion Standard and Precision Current Transformers
  1.  I/I type TH0500 can be used to calibrate DC current comparator, current transformer and other I/I conversion equipment according to the following two methods.
  2. Calibration by difference method: the selected TH0500 is in the same proportion as the tested I/I μA micro ammeter for calibration.
  3. Calibration by current ratio method: TH0500 selected is not in the same proportion as the tested I/I, and the current ratio measuring device is used for calibration
 
Establish high voltage and high current power/electric energy precision measurement system
TH0500 Current Conversion Standard and Precision Current Transformers
  1. TH0500 can be used with high-voltage V/V conversion equipment (typically TH0170 precision DC voltage divider) and standard power/energy meter (typically TD1310 AC/DC standard meter) to form a high-voltage high current power/energy precision measurement system.
  2. It is used to measure the output power of high-power power supply, the efficiency of conversion equipment, calibrate high-power power source, power meter and other equipment


4. Specifications

4.1 Direct Connected I/I Conversion Standard

Model Primary Test
Current
( A )
Secondary
Output Current
 ( A )
Transformation Ratio Accuracy 
( ± μA / A, full range)
DC AC@53Hz
TH0500-I-D-01A-01A-2 0.1 0.1 1:1 2 150
TH0500-I-D-02A-01A-2 0.2 0.1 2:1 2 150
TH0500-I-D-05A-01A-2 0.5 0.1 5:1 2 150
TH0500-I-D-1A-01A-2 1 0.1 10:1 2 150
TH0500-I-D-2A-01A-2 2 0.1 20:1 2 150
TH0500-I-D-5A-01A-2 5 0.1 50:1 2 150
TH0500-I-D-10A-01A-2 10 0.1 100:1 2 150
TH0500-I-D-20A-01A-2 20 0.1 200:1 2 150
TH0500-I-D-50A-01A-2 50 0.1 500:1 2 150
TH0500-I-D-100A-01A-2 100 0.1 1000:1 2 150
TH0500-I-D-200A-01A-2 200 0.1 2000:1 2 150
  1. Measurement range: ± (0~120%) * FS; Measuring frequency: DC~5 kHz (3dB signal bandwidth ≥ 100 kHz)

4.2 Through Core I/I Conversion Standard

Model Primary Test
Current
( A )
Secondary
Output Current
 ( A )
Transformation Ratio Accuracy 
( ± μA / A, full range)
DC AC@53Hz
TH0500-I-T-500A-01A-5 500 0.1 5000:1 5 150
TH0500-I-T-1kA-02A-5 1 k 0.2 5000:1 5 150
TH0500-I-T-2kA-05A-5 2 k 0.5 4000:1 5 150
TH0500-I-T-5kA-1A-5 5 k 1 5000:1 5 150
TH0500-I-T-10kA-2A-10 10 k 2 5000:1 10 150
TH0500-I-T-20kA-5A-20 20 k 5 4000:1 20 150
  1. Measurement range: ± (0~120%) * FS; Measuring frequency: DC~5 kHz (3dB signal bandwidth ≥ 100 kHz)
Note: The secondary nominal output current can be customized according to customer requirements.

4.3 Direct connected I/V conversion standard

Model Primary Test
Current
( A )
Secondary
Output Voltage
 ( V )
Accuracy
( ± 1×10-6, full range)
DC AC@53Hz
TH0500-U-D-01A-10V-10 0.1 10 10 200
TH0500-U-D-02A-10V-10 0.2 10 10 200
TH0500-U-D-05A-10V-10 0.5 10 10 200
TH0500-U-D-1A -10V-10 1 10 10 200
TH0500-U-D-2A-10V-10 2 10 10 200
TH0500-U-D-5A-10V-10 5 10 10 200
TH0500-U-D-10A-10V-10 10 10 10 200
TH0500-U-D-20-10V-10 20 10 10 200
TH0500-U-D-50A-10V-10 50 10 10 200
TH0500-U-D-100-10V-10 100 10 10 200
TH0500-U-D-200A-10V-10 200 10 10 200
TH0500-U-D-01A-10V-20 0.1 10 20 200
TH0500-U-D-02A-10V-20 0.2 10 20 200
TH0500-U-D-05A-10V-20 0.5 10 20 200
TH0500-U-D-1A-10V-20 1 10 20 200
TH0500-U-D-2A-10V-20 2 10 20 200
TH0500-U-D-5A-10V-20 5 10 20 200
TH0500-U-D-10A-10V-20 10 10 20 200
TH0500-U-D-20A-10V-20 20 10 20 200
TH0500-U-D-50A-10V-20 50 10 20 200
TH0500-U-D-100A-10V-20 100 10 20 200
TH0500-U-D-200A-10V-20 200 10 20 200
TH0500-U-D-01A-10V-50 0.1 10 50 200
TH0500-U-D-02A-10V-50 0.2 10 50 200
TH0500-U-D-05A-10V-50 0.5 10 50 200
TH0500-U-D-1A-10V-50 1 10 50 200
TH0500-U-D-2A-10V-50 2 10 50 200
TH0500-U-D-5A-10V-50 5 10 50 200
TH0500-U-D-10A-10V-50 10 10 50 200
TH0500-U-D-20A-10V-50 20 10 50 200
TH0500-U-D-50A-10V-50 50 10 50 200
TH0500-U-D-100A-10V-50 100 10 50 200
TH0500-U-D-200A-10V-50 200 10 50 200
  1. Measurement range: ± (0~120%) * FS; Measuring frequency: DC~5 kHz (3dB signal bandwidth ≥ 100 kHz)

4.4 Through Core I/V Conversion Standard

Model Primary Test
Current
( A )
Secondary
Output Voltage
 ( V )
Accuracy 
( ± 1×10-6, full range)
DC AC@53Hz
TH0500-U-T-500A-10V-10 500 10 10 200
TH0500-U-T-1kA-10V-10 1 k 10 10 200
TH0500-U-T-2kA-10V-10 2 k 10 10 200
TH0500-U-T-5kA-10V-10 5 k 10 10 200
TH0500-U-T-500A-10V-20 500 10 20 200
TH0500-U-T-1kA-10V-20 1 k 10 20 200
TH0500-U-T-2kA-10V-20 2 k 10 20 200
TH0500-U-T-5kA-10V-20 5 k 10 20 200
TH0500-U-T-10kA-10V-20 10 k 10 20 200
TH0500-U-T-500A-10V-50 500 10 50 200
TH0500-U-T-1kA-10V-50 1 k 10 50 200
TH0500-U-T-2kA-10V-50 2 k 10 50 200
TH0500-U-T-5kA-10V-50 5 k 10 50 200
TH0500-U-T-10kA-10V-50 10 k 10 50 200
TH0500-U-T-20kA-10V-50 20 k 10 50 200
 Measurement range: ± (0~120%) * FS; Measuring frequency: DC~5 kHz (3dB signal bandwidth ≥ 100 kHz)

5. General Specifications
 
Power Supply AC:195 V ~ 242 V / 47 Hz ~ 63 Hz
Lithium battery (built-in)
Temperature Performance Working temperature: 0 °C ~45 °C;
Storage temperature: -10 °C ~ 55 °C;
Humidity Performance Working humidity: 50% R·H,non-condensing;
Storage humidity:(15% ~ 80%)R·H,non-condensing.

6. Ordering Information
TH0500 Current Conversion Standard and Precision Current Transformers
 
Company Profile
 

TH0500 Current Conversion Standard and Precision Current Transformers

TH0500 Current Conversion Standard and Precision Current TransformersTH0500 Current Conversion Standard and Precision Current Transformers

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier